Description:

Highly purified E. coli gyrase is being offered as a holoenzyme (contains both A,B subunits).  This is an excellent reagent for supercoiling plasmids in vitro or for novel drug screens. 

 Quality Control Tests:

Nuclease contamination: assayed by testing for linear KDNA and linear plasmid DNA formation. Incubation of 1 µg of catenated KDNA or supercoiled pUC19 DNA for 4 hrs. at 37 C (under gyrase assay conditions and with or without ATP).

 Assay Conditions:

Supercoiling assays are carried out using relaxed pBR-322 DNA under conditions specified in the protocol sheets provided with the product.  We also perform assays using kDNA as substrate.  For details on this decatenation/supercoiling assay go here.  We also have some technical literature on assays: GO HERE.  One unit of gyrase activity will supercoil 0.25 ug pBR-322 DNA in 30 min at 37 C.

A 5X assay buffer and dilution buffer  is included with the enzyme. 

Storage and Shipping Conditions:

 The enzyme is shipped on dry ice and should be stored at -70 C. We also recommend that the enzyme be aliquoted after the first thaw (repeated rounds of freeze/thaw may cause loss of activity); the enzyme activity is stable for 1-3 days on ice. 

Catalog Number

Description

Size

2000G-1

DNA Gyrase

100 units

2000G-3

DNA Gyrase

500 units

2000G-5

DNA Gyrase

1000 units

2000G-7

DNA Gyrase

2000 units

Please enquire about bulk sales of DNA gyrase greater than 2000 Units. We offer discounts on bulk Gyrase above 2000 units. Contact us at topogen@aol.com for a quote.

If you are working with Gyrase, the following products will be of interest

Catalog Number

Description

Size

2000G1KIT

DNA Gyrase+relaxed DNA + Rxn Buffer

100 units

2013-1

kDNA substrate

25 ug

.

Purification data of Gyrase A and B SubunitsgyrABPAGE02

TopoGEN’s Gyrase is very stable and can be provided at high or low activity concentrationsgyrase stability expt

NEW LOW PRICES

We offer custom screening on a contract basis. Let us test your compounds for topo targeting activity.

Print our catalog in acrobat format (PDF).

E. coli DNA Gyrase

Technical Questions?
Email support@topogen.com

MAILING ADDRESS
TopoGEN, Inc.
108 Aces Alley
Port Orange, FL, USA 32128
info@topogen.com
Tel  614-451-5810
Fax  614-559-3932

Want to quantify your topo gel assay data or topo cleavage data?
GO HERE for more information.

Copyright TopoGEN, Inc., 2007
All rights reserved
Site Design by DNA Protein, Ltd.
Updated December 26, 2006